Now have support for 2-stage calibration sequence
This commit is contained in:
18
agenda.js
18
agenda.js
@@ -25,11 +25,23 @@ const initializeAgenda = async (mongoUri, pool, io) => { // Now accepts pgPool
|
||||
if (result.rowCount != 1) throw new Error("No such peripheral in database");
|
||||
|
||||
const {rows} = await sharedPgPool.query("select socket from device_tokens where device_id=$1 and connected=TRUE", [result.rows[0].device_id]);
|
||||
if (rows.length != 1) console.log("No device with that ID connected to Socket.");
|
||||
if (rows.length != 1) {
|
||||
console.log("No device with that ID connected to Socket.");
|
||||
// Notify user that device is not connected
|
||||
const {rows: userRows} = await sharedPgPool.query("select socket from user_tokens where user_id=$1", [userID]);
|
||||
if (userRows.length == 1 && userRows[0]) {
|
||||
socketIoInstance.to(userRows[0].socket).emit("calib_error", {
|
||||
periphID: result.rows[0].id,
|
||||
message: "Device not connected"
|
||||
});
|
||||
}
|
||||
// Reset await_calib since calibration cannot proceed
|
||||
await sharedPgPool.query("update peripherals set await_calib=FALSE where id=$1", [periphID]);
|
||||
}
|
||||
else {
|
||||
const socket = rows[0].socket;
|
||||
if (socket) {
|
||||
socketIoInstance.to(socket).emit("calib", {periphNum: result.rows[0].peripheral_number});
|
||||
socketIoInstance.to(socket).emit("calib_start", {port: result.rows[0].peripheral_number});
|
||||
}
|
||||
}
|
||||
|
||||
@@ -61,7 +73,7 @@ const initializeAgenda = async (mongoUri, pool, io) => { // Now accepts pgPool
|
||||
else {
|
||||
const socket = rows[0].socket;
|
||||
if (socket) {
|
||||
socketIoInstance.to(socket).emit("cancel_calib", {periphNum: result.rows[0].peripheral_number});
|
||||
socketIoInstance.to(socket).emit("cancel_calib", {port: result.rows[0].peripheral_number});
|
||||
}
|
||||
}
|
||||
} catch (error) {
|
||||
|
||||
Reference in New Issue